*Low price and high reliablity *105ºC Ootput capacitor *AC input power suitable for the world *High efficiency and low operation tenperature *Sofft-start current can reduce the AC input impact effecticly *With short-circuit and overload protectio *Compact size,light weight *100%full-load bum-in test *Installed with EMI filter, mlnlmum wave | ||||
Specification         ModelNo. |     S-201-5 |     S-201-12 |    S-201-24 |    S-201-48 |
DC output voltage | 5V | 12V |   24V | 48V |
Output voltage range (Note:2) |  ±2% |  ±1% |   ±1% |  ±1% |
Rated output current | 40A | 16.5A | 8.3A | 4.2A |
 output  current range |    0~40A | 0~16.5A | 0~8.3A | 0~4.2A |
Wave and noise (Note:3) | 75mVp-p | 75mVp-p | 75mVp-p | 75mVp-p |
Inlet stability (Note:4) |      ±0.5% |      ±0.5% |      ±0.5% |  ±0.5% |
Load stability (Note:5) |      ±0.1% |      ±0.5% |      ±0.5% |   ±0.5% |
DC output power | 201W | 201W | 201W | 201W |
Efficiency | Â 78% | 83% | 83% | Â 84% |
Adjustable range for DC voltage  | 4.5~5.6V | 10~13.2V | 20~26.4V | 41~56V |
AC input voltage range |  90-132VAC/ 180~264VAC  47~63Hz 254~370VDC | |||
output current | 3.6A/115V 1.8A/230 | |||
AC rush current | 25A/115V 50A/230V | |||
Leakage current | <3.5mA/240VAC | |||
Overload protection         |  105%-150% hiccup mode,auto-recovery | |||
Over-Voltage protection    | 5.75~6.75V/ 13.8~16.2V/18~21V/33.7~39.2V | |||
High-temperature protection | ERH3≥65ºC 70ºC Cfan  on,≤55ºC~60ºCCfan off,>80ºC~85ºC, Cut off output(5~15V)~(24~48V) |
|||
Temperaut re cofficient |  ±0.03%/ºC(0~50ºC) | |||
Setup,rise,hold up time |  200ms,100ms,20ms | |||
Vibration |  10~500Hz, 2G 10min,1 cycle Pariod for 60min, Each axes | |||
Withstand voltage  |  I/P-O/P:1.5Kv    I/P-FG:1.5KV   O/P-FG:0.5KV   1minute | |||
Insulation resistance |  I/P-O/P   IP/FG   OP-FG:500VDC/100MΩ  | |||
Working temperature and humidity |  -10ºC~+60ºC,20%~90%RH | |||
Overall dimension |  215*115*50 mm | |||
Safety Standards | Design refer to UL1950 | |||
EMC Standards | Design refer to FCC Part15J Class A | |||
Weight | 0.9Kgs | |||
Note: 1.The testina condition for The Paramenter is:230VAC input,rated load, 25ºC 70% RH Temperature 2.Error incude the seting error, line stability and load stability 3.Wave test:adopt in "A12"double wire for 20MHz,and 0.1 UF capacitor short-circuit for interrupt bug 4.Inlet voItage stability test:When is over load,the lowest voItage of inlet is up to the hiqhest voltaqe 5.Load stability test:the load is from 0% to 100% 6.C3,4 must be knocked dow | ||||
*Low price and high reliablity *105ºC Ootput capacitor *AC input power suitable for the world *High efficiency and low operation tenperature *Sofft-start current can reduce the AC input impact effecticly *With short-circuit and overload protectio *Compact size,light weight *100%full-load bum-in test *Installed with EMI filter, mlnlmum wave | ||||
Specification         ModelNo. |     S-201-5 |     S-201-12 |    S-201-24 |    S-201-48 |
DC output voltage | 5V | 12V |   24V | 48V |
Output voltage range (Note:2) |  ±2% |  ±1% |   ±1% |  ±1% |
Rated output current | 40A | 16.5A | 8.3A | 4.2A |
 output  current range |    0~40A | 0~16.5A | 0~8.3A | 0~4.2A |
Wave and noise (Note:3) | 75mVp-p | 75mVp-p | 75mVp-p | 75mVp-p |
Inlet stability (Note:4) |      ±0.5% |      ±0.5% |      ±0.5% |  ±0.5% |
Load stability (Note:5) |      ±0.1% |      ±0.5% |      ±0.5% |   ±0.5% |
DC output power | 201W | 201W | 201W | 201W |
Efficiency | Â 78% | 83% | 83% | Â 84% |
Adjustable range for DC voltage  | 4.5~5.6V | 10~13.2V | 20~26.4V | 41~56V |
AC input voltage range |  90-132VAC/ 180~264VAC  47~63Hz 254~370VDC | |||
output current | 3.6A/115V 1.8A/230 | |||
AC rush current | 25A/115V 50A/230V | |||
Leakage current | <3.5mA/240VAC | |||
Overload protection         |  105%-150% hiccup mode,auto-recovery | |||
Over-Voltage protection    | 5.75~6.75V/ 13.8~16.2V/18~21V/33.7~39.2V | |||
High-temperature protection | ERH3≥65ºC 70ºC Cfan  on,≤55ºC~60ºCCfan off,>80ºC~85ºC, Cut off output(5~15V)~(24~48V) |
|||
Temperaut re cofficient |  ±0.03%/ºC(0~50ºC) | |||
Setup,rise,hold up time |  200ms,100ms,20ms | |||
Vibration |  10~500Hz, 2G 10min,1 cycle Pariod for 60min, Each axes | |||
Withstand voltage  |  I/P-O/P:1.5Kv    I/P-FG:1.5KV   O/P-FG:0.5KV   1minute | |||
Insulation resistance |  I/P-O/P   IP/FG   OP-FG:500VDC/100MΩ  | |||
Working temperature and humidity |  -10ºC~+60ºC,20%~90%RH | |||
Overall dimension |  215*115*50 mm | |||
Safety Standards | Design refer to UL1950 | |||
EMC Standards | Design refer to FCC Part15J Class A | |||
Weight | 0.9Kgs | |||
Note: 1.The testina condition for The Paramenter is:230VAC input,rated load, 25ºC 70% RH Temperature 2.Error incude the seting error, line stability and load stability 3.Wave test:adopt in "A12"double wire for 20MHz,and 0.1 UF capacitor short-circuit for interrupt bug 4.Inlet voItage stability test:When is over load,the lowest voItage of inlet is up to the hiqhest voltaqe 5.Load stability test:the load is from 0% to 100% 6.C3,4 must be knocked dow | ||||